JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device
  • JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device

JHHS-HQ series SF6 mixed gas recovery and recharge purification and separation device

recommendation index:
Adopt PLC controller, 15-inch color LCD touch screen
Effective filtration and adsorption of decomposed impurities
Liquid SF6 can be filled into cylinders for storage after separation and recovery
High-efficiency filtration and maintenance-free system greatly guarantees the quality of recovered S
  • For rapid recovery, purification and separation of sulfur hexafluoride mixed gas

  • It is mainly composed of gas circuit system, vacuum system, evaporation and gasification system, gas pretreatment system, gas recovery and separation system, refrigeration liquefaction model system, exhaust gas treatment system, SF6 gas filling system, dynamic gas distribution system, pressurized gas charging system, gas detection system, gas storage tank and intelligent control system

  • Membrane separation technology or cryogenic solidification separation technology is used to separate the SF6 mixed gas, and the N2 gas is discharged into the atmosphere in a high-purity state after being cycled and infiltrated

project

Specifications

Model

JHHS10-HQ1

JHHS20-HQ1

JHHS30-HQ1

Mixing ratio detection (built-in)

Detect object

SF6/N2

Detection range

0 pio 100% (volume fraction)

Detection accuracy

± 0.5% (volume fraction)

Resolution

± 0.01% (volume fraction)

SF6 tail gas detection (built-in)

Detection sensitivity

≤1μL/L

Measurement error

≤±5%

Vacuum pump

 

Type

Two-stage rotary vane vacuum pump with solenoid valve for preventing oil return.

Vacuum flow

≥64m3/h

≥160m3/h

≥250m3/h

Limit vacuum

≤10Pa

Negative pressure recovery pump

Negative pressure recovery rate

≥ 30m3/h

≥ 60m3/h

≥ 120m3/h

Negative pressure recovery limit vacuum degree

≤100Pa


Related recommendations

JH6000HQ2-A4 SF6 gas mixture comprehensive detector

Detection function, high accuracy, good stability

JH6000HQ2-D4 SF6 Mixed Gas Comprehensive Detector

Detection function, high accuracy, good stability

JH6000HQ-3 SF6 gas mixing ratio detector

Low air consumption, good for environmental protection

Add wechat

Scan and add customer service wechat